We are all well aware that a major problem in the IT industry is that there is a lack of quality study materials.
This Blog provides you everything you will need to take a certification examination and Exam Preparation Material. Like actual certification exams, our Practice Tests are in Flydumps Our EMC E20-616 Exam will provide you with exam questions with verified answers that reflect the actual exam. These questions and answers provide you with the experience of taking the actual test. High quality and Value for the EMC E20-616 Exam:100% Guarantee to Pass Your https://www.leads4pass.com EMC E20-616 exam and get your EMC certification.
QUESTION 1
What is the maximum amount of cache that can be configured in a Symmetrix VMAX 20K?
A. 128 GB / engine 1 TB / array
B. 128 GB / engine 512 / array
C. 256 GB / engine 1 TB / array
D. 256 GB / engine 2 TB / array
Correct Answer: D
QUESTION 2
Which component types are installed in a VMAX 10K Storage Bay?
A. DAE, PDP, PDU, LCC
B. DAE, PDP, PDU, SPS
C. LCC, SPS, PDP, PDU
D. DAE, FAN, PDU, SPS
Correct Answer: A
QUESTION 3
What is the maximum number of drives that can be configured in a Symmetrix VMAX 10K (959)/VMAXe with Standard DAE configuration?
A. 3200
B. 2400
C. 1560
D. 1080
Correct Answer: D
QUESTION 4
What is the maximum number of 3.5 inch drives that can be configured in a Symmetrix VMAX 20K?
A. 2400
B. 3200
C. 1080
D. 1560
Correct Answer: A
QUESTION 5
A customer using a VMAX 20K containing 2 high density storage bays, each containing 250 drives wants to expand their capacity with 100 drives.
What is the least expensive way to expand the existing configuration, but still a good choice for optimal performance in this configuration?
A. Add two DAEs to each storage bay, each containing 25 drives
B. Add four DAEs to the first storage bay, each containing 25 drives
C. Add two storage bays, one to each loop and each bay containing 2 DAEs with 25 drives each
D. Add one storage bay containing four DAEs with 25 drives each to the first loop
Correct Answer: A QUESTION 6
A customer using a VMAX 20K containing 2 standard storage bays, each containing 90 drives wants to expand their capacity to 120 drives. What is the least expensive way to expand the existing configuration, but still a good choice for optimal performance in this configuration?
A. Add four DAEs to each storage bay, each containing 15 drives
B. Add eight DAEs to the first storage bay, each containing 15 drives
C. Add two storage bays, one to each loop and each bay containing four DAEs with 15 drives each
D. Add one storage bay containing eight DAEs with 15 drives each to the first loop
Correct Answer: A QUESTION 7
In a cascaded SRDF/EDP configuration, which device type is used as a cache only device?
A. R21
B. R22
C. R11
D. Standard Clone
Correct Answer: A QUESTION 8
Which SRDF/A feature offloads from cache to a dedicated device pool?
A. Delta Set Extension
B. Write Pacing
C. Transmit Idle
D. SRDF Compression
Correct Answer: A QUESTION 9
Which SRDF/A feature prevents cache overflow on either the R1 or R2 devices?
A. Write Pacing
B. Transmit Idle
C. SRDF Compression
D. Delta Set Extension
Correct Answer: A QUESTION 10
Which set of interface types support hardware compression on VMAX 40K?
A. 10 GigE and FC
B. FC and FCoE
C. FCoE and 10 GigE
D. 1 GigE and FCoE
Correct Answer: A QUESTION 11
Which set of VMAX interface types support software compression with SRDF?
A. FC and 10 GigE
B. FCoE and FC
C. 10 GigE and FCoE
D. Ficon and 10 GigE
Correct Answer: A
QUESTION 12
What is the status of the R1 and R2 devices after a SRDF Split operation is performed?
A. R1 is Read-Write R2 is Read-Write
B. R1 is Read-Write R2 is Read-Only
C. R1 is Write Disabled R2 is Read-Write
D. R1 is Read-Only R2 is Read-Write
Correct Answer: A
QUESTION 13
What is the status of the R1 and R2 devices after a SRDF Failback operation is performed?
A. R1 is Read-Write R2 is Write Disabled
B. R1 is Write Disabled R2 is Read-Write
C. R1 is Read-Write R2 is Read-Only
D. R1 is Read-Only R2 is Read-Write
Correct Answer: A
QUESTION 14
Which SRDF operation results in a suspended link?
A. Split
B. Swap
C. Failback
D. Restore
Correct Answer: A
QUESTION 15
Which two SRDF operations will result in a suspended link?
A. Split and Failover
B. Restore and Split
C. Failover and Swap
D. Split and Failback
Correct Answer: A
QUESTION 16
A new customer has purchased a VMAX 10K array. During implementation they explain requirements for one application that requires a point-in-time copy of the primary volumes every six hours, and retention for seven days. The change rate is expected to be low.
Which replication solution should be recommended?
A. TimeFinder VP Snap
B. TimeFinder/Snap
C. RecoverPoint CDP
D. TimeFinder/Clone
Correct Answer: A QUESTION 17
A new customer has purchased a VMAX 40K array. During implementation they explain requirements for one application that requires a point-in-time copy of the primary volumes every 2 hours, and retention for three days. The change rate is expected to be low.
Which replication solution should be recommended?
A. TimeFinder/Snap
B. TimeFinder/Clone
C. TimeFinder/VP Snaps
D. TimeFinder/Mirror
Correct Answer: A QUESTION 18
When using TimeFinder/Clone, when does the target device become read/write available to the target host?
A. After Activation
B. During the Create Session process
C. After a full background copy completes
D. Before Activation
Correct Answer: A QUESTION 19
Which point-in-time protection mechanism is used by TimeFinder/VP Snap?
A. Copy on Access
B. Full Background Copy
C. Pre-copy Option
D. Copy on First Write
Correct Answer: A QUESTION 20
In a VMAX 20K extended drive loop configuration also known as capacity configurations, what is the maximum number of engines you can install?
A. 4
B. 2
C. 6
D. 8
Correct Answer: A QUESTION 21
You’re a sales representative and trying to position VMAX for a customer environment.
The customer requirements are:
Maximum Performance
Large Scale Consolidation
Supports IBM System z & i
Up to 3,200 disks
Which family of VMAX would support these requirements?
A. VMAX 40K
B. VMAX 10K (959)
C. VMAX 20K
D. VMAX 10K (987)
Correct Answer: A
Flydumps.com never believes in second chances and hence bring you the best EMC E20-616 exam preparation materials which will make you pass in the first attempt. Flydumps.com experts have complied the fail EMC E20-616 exam content to help you pass your EMC E20-616 certification exam in the first attempt and score the top possible grades too.